{"title":"Calibration Furnaces","description":null,"products":[{"product_id":"pr330-thermocouple-calibration-furnace-with-multiple-calorifiers","title":"PR330 Thermocouple Calibration Furnace with Multiple Calorifiers","description":"\u003cdiv class=\"fl-builder-content fl-builder-content-5192 fl-builder-content-primary fl-builder-global-templates-locked\" data-post-id=\"5192\"\u003e\n\u003cdiv class=\"fl-row fl-row-full-width fl-row-bg-none fl-node-645d95c112c9d\" data-node=\"645d95c112c9d\"\u003e\u003cdiv class=\"fl-row-content-wrap\"\u003e\u003cdiv class=\"fl-row-content fl-row-full-width fl-node-content\"\u003e\u003cdiv class=\"fl-col-group fl-node-645d95c112cdc\" data-node=\"645d95c112cdc\"\u003e\u003cdiv class=\"fl-col fl-node-645d95c112d1a\" data-node=\"645d95c112d1a\" style=\"width: 100%;\"\u003e\u003cdiv class=\"fl-col-content fl-node-content\"\u003e\n\u003cdiv class=\"fl-module fl-module-rich-text fl-node-645d95c112d94\" data-node=\"645d95c112d94\" data-animation-delay=\"0.0\"\u003e\u003cdiv class=\"fl-module-content fl-node-content\"\u003e\u003cdiv class=\"fl-rich-text\"\u003e\n\u003ch3\u003e\u003cstrong\u003eOverview:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe verification furnace or calibration furnace isan important part of the medium and high temperature traceability system. In general,the traditional verification furnace orcalibration furnace is a horizontal electric furnace with simple structure. The temperature uniformity of the effective working area of the furnace can not be well controlled, and the temperature uniformity of the furnace is prone to deviation after the furnace has been used for a long time.Even if the temperatureuniformityof thefurnace is improved to a certain extent by adding metal thermostatic block, its overall technical performance is still not ideal, which is the main source of uncertainty in the process of thermocouple verification and calibration.Therefore, the traditional verification furnaceor calibration furnace cannot meet the requirements of high-precision temperature traceability in terms of structure. PR330 series calibration furnace with multiple calorifiersadopts a subversive design scheme from the internal structure to the control method, and has made a qualitative leap in key technical parameters.\u003c\/p\u003e\n\u003cp\u003ePR330 series calibration furnace with multiple calorifiers adoptsinnovative technologies such as controlling with multiple calorifiers, DC heating, load balancing, active heat dissipation, and embedded temperature control sensor to extend its working temperature to 100°C~1300°C. With excellent temperature uniformity and temperature stability covering the entire temperature range, the calibration furnacegreatly reduces the uncertainty in the temperature traceability process. In addition, thecalibration furnace possessespowerful human interface function, communication function, and many humanized designs including front and rear dual display screens and hidden scales.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e■ Characteristics of wide temperature uniformity over the entire temperature range\u003cbr\u003eAdoptingtheheating technologywith multiple calorifiers, the power distribution ratio of different parts of the furnace body heating cavity can be calculated in real time according to the current set temperature and heat dissipation conditions, and the ideal temperature uniformity can be achieved at any temperature point without the thermostatic block.\u003c\/p\u003e\n\u003cp\u003e■ Wider working temperature range\u003cbr\u003eWith many new designs in the furnace structure and materials, the working temperature range of the calibration furnace is extended to 100 ℃ ~ 1300 ℃. The calibration furnace can be operated at 1300℃ for a short time or 1250℃ for a long time. The minimum control temperature can be as low as 100 ℃, which further widens the temperature calibration range of thermocouple.\u003c\/p\u003e\n\u003cp\u003e■ The temperature stability is better than 0.15 ℃ \/ 10min\u003cbr\u003eIntegrated new generation PR2601 master controller of PANRAN, with 0.01 level of electrical measurement accuracy, and according to the control requirements of the calibration furnace, the calibration furnace has made targeted optimizations in terms of measurement speed, reading noise, control logic. And its full-range temperature stability is better than 0.15℃\/10min.\u003c\/p\u003e\n\u003cp\u003e■ Embedded temperature control thermocouple\u003cbr\u003eIn order to make the process of placing the calibrated sensor more convenient, a detachable temperature control thermocouple is embedded in the inner wall of the heating chamber, which will neither affect the insertion of other sensors nor adversely affect the temperature control process.\u003c\/p\u003e\n\u003cp\u003e■ High security\u003cbr\u003eThe power components of PR330 series multi-zone temperature calibration furnaces adopt full DC drive, which can avoid the disturbance caused by electric leakage at high temperature and other high voltage safety hazards from the source. The shell has an independent heat dissipation air duct, which can effectively reduce the temperature of the furnace surface when working at high temperature and avoid scalding caused by misoperation.\u003c\/p\u003e\n\u003cp\u003e■ Load balancing function\u003cbr\u003eBy adding an extra thermocouple to monitor the change of axial temperature uniformity in the heating chamber in real time, PR330 series multi-zone temperature calibration furnaces can adjust the power distribution ratio in real time to offset the influence of load insertion and maintain the optimal axial temperature uniformity, so as to meet the higher requirements of calibration.\u003c\/p\u003e\n\u003cp\u003e■ Powerful software and hardware function\u003cbr\u003eThe front touch screen can display general measurement and control parameters, and can perform operations such as timing switch, temperature stability setting, and WIFI setting. In order to facilitate the observation of real-time temperature from multiple angles, a secondary display with stability indication is also installed at the rear of the calibration furnace.\u003c\/p\u003e\n\u003cp\u003ePR9149C oil-water separator\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003cdiv class=\"fl-module fl-module-photo fl-node-645d96f8552f1\" data-node=\"645d96f8552f1\" data-animation-delay=\"0.0\"\u003e\u003cdiv class=\"fl-module-content fl-node-content\"\u003e\u003cdiv class=\"fl-photo fl-photo-align-center\" itemscope=\"\" itemtype=\"http:\/\/schema.org\/ImageObject\"\u003e\u003cdiv class=\"fl-photo-content fl-photo-img-png\"\u003e\u003cimg class=\"fl-photo-img wp-image-5198\" src=\"\/\/www.panrancalibration.com\/uploads\/1683855059606.png\" alt=\"1683855059606\" itemprop=\"image\"\u003e\u003c\/div\u003e\u003c\/div\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/div\u003e\u003c\/div\u003e\u003c\/div\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003cdiv class=\"fl-row fl-row-full-width fl-row-bg-none fl-node-645d9690ed185\" data-node=\"645d9690ed185\"\u003e\u003cdiv class=\"fl-row-content-wrap\"\u003e\u003cdiv class=\"fl-row-content fl-row-full-width fl-node-content\"\u003e\u003cdiv class=\"fl-col-group fl-node-645d9690ee649\" data-node=\"645d9690ee649\"\u003e\u003cdiv class=\"fl-col fl-node-645d9690ee80c\" data-node=\"645d9690ee80c\" style=\"width: 100%;\"\u003e\u003cdiv class=\"fl-col-content fl-node-content\"\u003e\u003cdiv class=\"fl-module fl-module-rich-text fl-node-645d9690ecff6\" data-node=\"645d9690ecff6\" data-animation-delay=\"0.0\"\u003e\u003cdiv class=\"fl-module-content fl-node-content\"\u003e\u003cdiv class=\"fl-rich-text\"\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.panrancalibration.com\/uploads\/16838558024071.png\"\u003e\u003cimg class=\"aligncenter size-full wp-image-5200\" alt=\"1683855802407(1)\" src=\"https:\/\/www.panrancalibration.com\/uploads\/16838558024071.png\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Model\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.panrancalibration.com\/uploads\/1683855764802.png\"\u003e\u003cimg class=\"aligncenter size-full wp-image-5199\" alt=\"1683855764802\" src=\"https:\/\/www.panrancalibration.com\/uploads\/1683855764802.png\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/div\u003e\u003c\/div\u003e\u003c\/div\u003e\u003c\/div\u003e\u003c\/div\u003e\u003c\/div\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c!----\u003e\u003cdiv class=\"clear\"\u003e\u003c\/div\u003e","brand":"Warehouse","offers":[{"title":"Default Title","offer_id":53792150945976,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/7224\/3128\/files\/645b11a023a2d.jpg?v=1784607265"},{"product_id":"pr325a-thermocouple-calibration-furnace","title":"PR325A Thermocouple Calibration Furnace","description":"\u003cp\u003e \u003c\/p\u003e\u003cdiv\u003e\n\u003cp\u003ePR325A \u003ca href=\"https:\/\/www.panrancalibration.com\/thermocouple-calibration-furnace\/\" title=\"View all posts in Thermocouple Calibration Furnace\" target=\"_blank\"\u003eThermocouple Calibration Furnace\u003c\/a\u003e has excellent performance and rich functions. It adopts a new structural design, has a longer service life, and solves the problems of furnace positioning and high temperature electric leakage through the built-in metal positioner.\u003c\/p\u003e\n\u003cp\u003eThe control part uses part of the technology of the PR330 Multi-zone \u003ca href=\"https:\/\/www.panrancalibration.com\/temperature-calibration-furnace\/\" title=\"View all posts in Temperature Calibration Furnace\" target=\"_blank\"\u003eTemperature Calibration Furnace\u003c\/a\u003e, which has the ability to adjust the axial temperature uniformity slightly. Compared with the traditional thermocouple calibration furnace, better verification or calibration results can be obtained without a isothermal block.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/\/cdn.globalso.com\/panrancalibration\/1672820740148556.png\"\u003e\u003cimg class=\"aligncenter\" alt=\"1672820740148556\" src=\"\/\/cdn.globalso.com\/panrancalibration\/1672820740148556.png\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eI. Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNo need for a\u003c\/strong\u003e\u003cstrong\u003eisothermal\u003c\/strong\u003e\u003cstrong\u003eblock, and the axial temperature uniformity over the full range is better than 1°C\/6cm\u003c\/strong\u003e\u003cstrong\u003e \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe controller can automatically adjust the balance power at both ends, and can obtain 1°C\/6cm axial temperature uniformity without a isothermal block in the temperature range of 300°C~1200°C, which can effectively reduce the uncertainty of the verification or calibration process.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIntegrated high-accuracy temperature controller and reference compensator\u003c\/strong\u003e\u003cstrong\u003e \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eUsing PR2601 temperature controller, it has a measurement accuracy of 0.01. With the special reference end compensator, the accuracy is better than 0.6℃+0.1%RD when using type N temperature-controlled thermocouple.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBuilt-in positioner for easy sensor positioning\u003c\/strong\u003e\u003cstrong\u003e \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe bottom of the built-in metal positioner is 32cm away from the test end of the furnace mouth, and the furnace loading operation can be completed by simply inserting the sensor into the bottom of the positioner.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHigh temperature electric\u003c\/strong\u003e\u003cstrong\u003e \u003c\/strong\u003e\u003cstrong\u003eleakage suppression\u003c\/strong\u003e\u003cstrong\u003e \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe ground terminal is reserved externally, and after connecting the metal positioner, the influence of leakage at high temperature on the electrical measuring instrument can be effectively suppressed.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eL\u003c\/strong\u003e\u003cstrong\u003eonger service life\u003c\/strong\u003e\u003cstrong\u003e \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eUnder the same operating conditions, by increasing the load capacity of the internal heating wire, the service life of several times the traditional calibration furnace can be obtained.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRich software and hardware functions\u003c\/strong\u003e\u003cstrong\u003e \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eUsing the front color touch screen, it can display and set general measurement and control parameters, and can also perform operations such as timed power on and off, temperature stability settings, and WIFI settings.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eII. Other\u003c\/strong\u003e\u003cstrong\u003eF\u003c\/strong\u003e\u003cstrong\u003eunctions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" valign=\"top\" width=\"552\"\u003eOther Functions\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\" width=\"276\"\u003eTemperature control sensor multi-temperature point correctionAdaptive temperature control parametersReal-time temperature, power curve display\u003cp\u003e\u003c\/p\u003e\n\u003cp\u003eBuilt-in reference junction compensation\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"276\"\u003eCustom temperature fluctuation calculationCustom alarm temperature upper and lower limitsBluetooth, WIFI expandable\u003cp\u003e\u003c\/p\u003e\n\u003cp\u003eOptional units \u003ca\u003e°C\u003c\/a\u003e, °F, K\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eIII.\u003c\/strong\u003e\u003cstrong\u003e \u003c\/strong\u003e\u003cstrong\u003eTechnical Parameters\u003c\/strong\u003e\u003cstrong\u003e \u003c\/strong\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003eProduct selection and technical parameters\u003c\/strong\u003e\u003cstrong\u003e \u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\" width=\"143\"\u003eModel\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"265\"\u003ePR325A\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"146\"\u003eRemarks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\" width=\"143\"\u003eWorking temperature range\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"265\"\u003e300℃~1200℃\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"146\"\u003e\/\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\" width=\"143\"\u003eFurnacecavity dimension\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"265\"\u003eφ40mm×600mm\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"146\"\u003e\/\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\" width=\"143\"\u003eTemperature control accuracy\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"265\"\u003e 0.5℃, when ≤500℃              0.1%RD, when＞500℃\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"146\"\u003eGeometric center point temperature of the furnacecavity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\" width=\"143\"\u003e60mm axial temperature field uniformity\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"265\"\u003e≤1.0℃\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"146\"\u003e300℃~1200℃ Furnacecavitygeometric center ±30mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\" width=\"143\"\u003eRadial temperature field uniformity\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"265\"\u003e≤0.4℃\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"146\"\u003eFurnacecavitygeometric center\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\" width=\"143\"\u003eTemperature stability\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"265\"\u003e≤0.3℃\/10min\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"146\"\u003e\/\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cstrong\u003eGeneral technical parameters\u003c\/strong\u003e\u003cstrong\u003e \u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\" width=\"144\"\u003eItem\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"408\"\u003eParameters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\" width=\"144\"\u003eDimensions\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"408\"\u003e700×370×500mm (L×W×H)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\" width=\"144\"\u003eDisplay screen\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"408\"\u003e4.0-inch industrial touch screen with a resolution of 800×480 pixels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\" width=\"144\"\u003eCommunication method\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"408\"\u003eRS232 (Standard), WiFi, Bluetooth (Optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\" width=\"144\"\u003eWeight\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"408\"\u003e55kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\" width=\"144\"\u003eRated power\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"408\"\u003e3kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\" width=\"144\"\u003ePower supply\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"408\"\u003e220VAC±10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\" width=\"144\"\u003eWorking environment\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"408\"\u003e-5~35℃,0~80%RH,Non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\" width=\"144\"\u003eStorage environment\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"408\"\u003e-20~70℃,0~80%RH,Non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c!----\u003e\u003cdiv class=\"clear\"\u003e\u003c\/div\u003e","brand":"Warehouse","offers":[{"title":"Default Title","offer_id":53792151273656,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/7224\/3128\/files\/dthdf-2.png?v=1784607274"},{"product_id":"pr331-short-multi-zone-temperature-calibration-furnace","title":"PR331 Short Multi-zone Temperature Calibration Furnace","description":"\u003cp\u003e\u003cimg title=\"1662099588939707.png\" alt=\"9f118308418ffc54994b3e36d30b385.png\" src=\"\/\/www.panrancalibration.com\/uploads\/1662099588939707.png\"\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eKeywords:\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003el \u003c\/span\u003e\u003cspan\u003eShort type, thin film thermocouples calibration\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003el \u003c\/span\u003e\u003cspan\u003eAre heated at three-zones\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003el \u003c\/span\u003e\u003cspan\u003eThe position of uniform temperature field is adjustable\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e \u003c\/p\u003e\u003cp\u003e\u003cspan\u003e\u003cspan\u003eⅠ.Overview\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e \u003c\/p\u003e\u003cp\u003e\u003cspan\u003e\u003cspan\u003ePR331 short-type temperature calibration furnace is specially used to calibrate \u003c\/span\u003e\u003cspan\u003eshort-type, thin-film thermocouples. It has the function of adjusting the position of the \u003c\/span\u003e\u003cspan\u003euniform temperature field. The uniform temperature field position can be selected according \u003c\/span\u003e\u003cspan\u003eto the length of the calibrated sensor.\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003e\u003cspan\u003eUsing innovative technologies such as multi-zone coupling control, DC heating, active \u003c\/span\u003e\u003cspan\u003eheat dissipation, etc., it has excellent \u003c\/span\u003e\u003cspan\u003etemperature field uniformity and temperature \u003c\/span\u003e\u003cspan\u003efluctuation covering the full temperature range\u003c\/span\u003e\u003cspan\u003e, greatly reducing the uncertainty in the \u003c\/span\u003e\u003cspan\u003etraceability process of short thermocouples.\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e \u003c\/p\u003e\u003cp\u003e \u003c\/p\u003e\u003cp\u003e\u003cspan\u003e\u003cspan\u003eⅡ.Features\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e \u003c\/p\u003e\u003cp\u003e\u003cspan\u003e\u003cspan\u003e1. The position of uniform temperature field is adjustable\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003e\u003cspan\u003eUsing \u003c\/span\u003e\u003cspan\u003ethree-temperature zone heating \u003c\/span\u003e\u003cspan\u003etechnology, it is convenient to adjust the uniform \u003c\/span\u003e\u003cspan\u003etemperature field position. In order to better match thermocouples of different lengths, the \u003c\/span\u003e\u003cspan\u003eprogram presets the front, middle and rear options to correspond to the uniform \u003c\/span\u003e\u003cspan\u003etemperature field at three different positions.\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003e\u003cspan\u003e2. \u003c\/span\u003e\u003cspan\u003eThe full range temperature stability is better than 0.15\u003c\/span\u003e\u003cspan\u003e℃\u003c\/span\u003e\u003cspan\u003e\/10min\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003e\u003cspan\u003eIntegrated with Panran’s new-generation PR2601 main controller, with 0.01% electrical \u003c\/span\u003e\u003cspan\u003emeasurement accuracy, and according to the control requirements of the calibration furnace, \u003c\/span\u003e\u003cspan\u003eit has made targeted optimizations in measurement speed, reading noise, control logic, etc., \u003c\/span\u003e\u003cspan\u003eand its full-range temperature stability better than 0.15\u003c\/span\u003e\u003cspan\u003e℃\u003c\/span\u003e\u003cspan\u003e\/10min.\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003e\u003cspan\u003e3. Full DC drive with active heat dissipation\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003e\u003cspan\u003eThe internal power components are \u003c\/span\u003e\u003cspan\u003edriven by full DC\u003c\/span\u003e\u003cspan\u003e, which avoids the disturbance and \u003c\/span\u003e\u003cspan\u003eother high voltage safety hazards caused by leakage at high temperature from the source. At \u003c\/span\u003e\u003cspan\u003ethe same time, the controller will automatically adjust the ventilation volume of the outer \u003c\/span\u003e\u003cspan\u003ewall of the insulation layer according to the current working conditions, so that the \u003c\/span\u003e\u003cspan\u003etemperature in the furnace cavity can reach the equilibrium state as soon as possible.\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003e\u003cspan\u003e4. Various types of thermocouples are available for temperature control\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003e\u003cspan\u003eThe size and shape type of short thermocouples are quite different. In order to adapt to \u003c\/span\u003e\u003cspan\u003edifferent thermocouples to be calibrated more flexibly, a thermocouple socket with \u003c\/span\u003e\u003cspan\u003eintegrated reference terminal compensation is designed, which can be quickly connected to \u003c\/span\u003e\u003cspan\u003etemperature-controlled thermocouples of various index numbers.\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003e\u003cspan\u003e5. Powerful software and hardware function\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003e\u003cspan\u003eThe touch screen can display general measurement and control parameters, and can perform \u003c\/span\u003e\u003cspan\u003eoperations such as timing switch, temperature stability setting, and WIFI settings.\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e \u003c\/p\u003e\u003cp\u003e\u003cspan\u003e\u003cspan\u003e\u003cspan\u003eⅢ.Specifications\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e \u003c\/p\u003e\u003cp\u003e\u003cspan\u003e\u003cspan\u003e\u003cspan\u003e\u003cspan\u003e1. Product Model and Specifications\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\u003ctable style=\"width: 561px;\"\u003e\u003ctbody\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd valign=\"center\" width=\"153\"\u003e\u003cspan\u003ePerformance\/Model\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"111\"\u003e\u003cspan\u003ePR331A\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" valign=\"center\" width=\"111\"\u003e\u003cspan\u003ePR331B\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"185\"\u003e\u003cspan\u003e\u003cspan\u003eRemarks\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\" width=\"153\"\u003e\n\u003cspan\u003e\u003cspan\u003eP\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003eosition of uniform temperature field is adjustable\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"111\"\u003e\u003cspan\u003e\u003cspan\u003e●\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" valign=\"center\" width=\"111\"\u003e\u003cspan\u003e\u003cspan\u003e○\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"185\"\u003e\n\u003cspan\u003eOptional deviation\u003c\/span\u003e\u003cspan\u003e\u003cspan\u003eg\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003eeometric center of the chamber of the furnace\u003c\/span\u003e\u003cspan\u003e\u003cspan\u003e±50 mm\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\" width=\"153\"\u003e\u003cspan\u003e\u003cspan\u003eTemperature range\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"3\" valign=\"center\" width=\"222\"\u003e\u003cspan\u003e\u003cspan\u003e300℃～1200℃\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"185\"\u003e\u003cspan\u003e\/\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\" width=\"153\"\u003e\u003cspan\u003eDimension of the chamber of the furnace\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"3\" valign=\"center\" width=\"222\"\u003e\u003cspan\u003e\u003cspan\u003eφ40mm×300mm\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"185\"\u003e\u003cspan\u003e\/\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\" width=\"153\"\u003e\u003cspan\u003eTemperature control accuracy\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"3\" valign=\"center\" width=\"222\"\u003e\n\u003cspan\u003e\u003cspan\u003e0.5℃，\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan\u003ewhen \u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan\u003e≤500℃\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan\u003e0.1%RD，\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan\u003ewhen \u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan\u003e＞\u003c\/span\u003e\u003cspan\u003e500℃\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"185\"\u003e\u003cspan\u003eTemperature at the center of the temperature field\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\" width=\"153\"\u003e\u003cspan\u003e60mm axial temperature uniformity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" valign=\"center\" width=\"117\"\u003e\u003cspan\u003e\u003cspan\u003e≤0.5℃ \u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"106\"\u003e\u003cspan\u003e\u003cspan\u003e≤1.0℃\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"185\"\u003e\n\u003cspan\u003eGeometric center of the chamber of the furnace\u003c\/span\u003e\u003cspan\u003e\u003cspan\u003e±\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan\u003e3\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e0mm\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\" width=\"153\"\u003e\n\u003cspan\u003e60 mm axial\u003c\/span\u003e\u003cspan\u003etemperature gradient\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"3\" valign=\"center\" width=\"222\"\u003e\u003cspan\u003e\u003cspan\u003e≤0.3℃\/10mm\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"185\"\u003e\n\u003cspan\u003eGeometric center of the chamber of the furnace\u003c\/span\u003e\u003cspan\u003e\u003cspan\u003e±\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan\u003e3\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e0mm\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\" width=\"153\"\u003e\n\u003cspan\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003eradial temperature uniformity\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"3\" valign=\"center\" width=\"222\"\u003e\u003cspan\u003e\u003cspan\u003e≤0.2℃\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"185\"\u003e\u003cspan\u003eGeometric center of the chamber of the furnace\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\" width=\"153\"\u003e\u003cspan\u003eTemperature stability\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"3\" valign=\"center\" width=\"222\"\u003e\u003cspan\u003e\u003cspan\u003e≤0.15℃\/10min\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"185\"\u003e\u003cspan\u003e\/\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cspan\u003e2. General Specifications\u003c\/span\u003e\u003c\/p\u003e\u003ctable style=\"width: 552px;\"\u003e\u003ctbody\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd valign=\"center\" width=\"155\"\u003e\u003cspan\u003e\u003cspan\u003eDimension\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"397\"\u003e\n\u003cspan\u003e370×250×500mm\u003c\/span\u003e\u003cspan\u003e\u003cspan\u003e(L*W*H)\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\" width=\"155\"\u003e\u003cspan\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"397\"\u003e\u003cspan\u003e20kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\" width=\"155\"\u003e\u003cspan\u003e\u003cspan\u003ePower\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"397\"\u003e\u003cspan\u003e1.5kW\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\" width=\"155\"\u003e\u003cspan\u003ePower supply condition\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"397\"\u003e\u003cspan\u003e220VAC±10%\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\" width=\"155\"\u003e\u003cspan\u003eWorking environment\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"397\"\u003e\n\u003cspan\u003e-5\u003cspan\u003e～\u003c\/span\u003e\u003cspan\u003e35℃\u003c\/span\u003e\u003cspan\u003e， \u003c\/span\u003e\u003cspan\u003e0\u003c\/span\u003e\u003cspan\u003e～\u003c\/span\u003e\u003cspan\u003e80%RH\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan\u003e, non-condensing\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\" width=\"155\"\u003e\u003cspan\u003eStorage environment\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"397\"\u003e\n\u003cspan\u003e-20\u003cspan\u003e～\u003c\/span\u003e\u003cspan\u003e70℃\u003c\/span\u003e\u003cspan\u003e，\u003c\/span\u003e\u003cspan\u003e0\u003c\/span\u003e\u003cspan\u003e～\u003c\/span\u003e\u003cspan\u003e80%RH\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan\u003e, non-condensing\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e \u003c\/p\u003e\u003cp\u003e \u003c\/p\u003e\u003c!----\u003e\u003cdiv class=\"clear\"\u003e\u003c\/div\u003e","brand":"Warehouse","offers":[{"title":"Default Title","offer_id":53792151470264,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/7224\/3128\/files\/d3139aa4.jpg?v=1784607278"},{"product_id":"pr320-thermocouple-calibration-furnace","title":"PR320 Thermocouple Calibration Furnace","description":"\u003cdiv\u003e\n\u003cspan style=\"font-size: medium; font-family: 'times new roman', times;\"\u003e\u003cb\u003eOverview\u003c\/b\u003e\u003c\/span\u003e\u003cp\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-family: 'times new roman', times; font-size: small;\"\u003eThe PR320 series thermocouple calibration furnaces feature built-in different temperature field accessories, which can meet the verification\/calibration needs of thermocouples with different types. This product complies with the requirements of JJF 1184-2024 “Test Specification for Temperature Uniformity in \u003ca href=\"https:\/\/www.panrancalibration.com\/thermocouple-calibration-furnace\/\" title=\"View all posts in Thermocouple Calibration Furnace\" target=\"_blank\"\u003eThermocouple Calibration Furnace\u003c\/a\u003es”, and features a wide temperature field range, fast heating and cooling speeds, and excellent long-term stability.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-family: 'times new roman', times; font-size: small;\"\u003e\u003cspan style=\"font-size: medium;\"\u003e\u003cb\u003eTechnical Parameters\u003c\/b\u003e\u003c\/span\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-family: 'times new roman', times; font-size: small;\"\u003e\u003cb\u003eGeneral Technical Parameters\u003c\/b\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable border=\"1\" cellspacing=\"0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\" width=\"210\"\u003e\u003cp align=\"center\"\u003e\u003cspan style=\"font-family: 'times new roman', times; font-size: small;\"\u003eFurnace cavity dimension\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"617\"\u003e\u003cp align=\"center\"\u003e\u003cspan style=\"font-family: 'times new roman', times; font-size: small;\"\u003eΦ40mm×600mm\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\" width=\"210\"\u003e\u003cp align=\"center\"\u003e\u003cspan style=\"font-family: 'times new roman', times; font-size: small;\"\u003eDimensions\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"617\"\u003e\u003cp align=\"center\"\u003e\u003cspan style=\"font-family: 'times new roman', times; font-size: small;\"\u003e680mm×520mm×380mm\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\" width=\"210\"\u003e\u003cp align=\"center\"\u003e\u003cspan style=\"font-family: 'times new roman', times; font-size: small;\"\u003eWeight\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"617\"\u003e\u003cp align=\"center\"\u003e\u003cspan style=\"font-family: 'times new roman', times; font-size: small;\"\u003e33kg\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\" width=\"210\"\u003e\u003cp align=\"center\"\u003e\u003cspan style=\"font-family: 'times new roman', times; font-size: small;\"\u003eRated power\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"617\"\u003e\u003cp align=\"center\"\u003e\u003cspan style=\"font-family: 'times new roman', times; font-size: small;\"\u003e2.5kw\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\" width=\"210\"\u003e\u003cp align=\"center\"\u003e\u003cspan style=\"font-family: 'times new roman', times; font-size: small;\"\u003eWorking environment\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"617\"\u003e\u003cp align=\"center\"\u003e\u003cspan style=\"font-family: 'times new roman', times; font-size: small;\"\u003e(-5～35)℃,  (0～80)%RH, non-condensing\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003e\u003cspan style=\"font-family: 'times new roman', times; font-size: small;\"\u003e\u003cb\u003e \u003c\/b\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\u003cp\u003e\u003cspan style=\"font-family: 'times new roman', times; font-size: small;\"\u003e\u003cb\u003eTemperature Field \u003c\/b\u003e\u003cb\u003eS\u003c\/b\u003e\u003cb\u003epecification\u003c\/b\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/span\u003e\u003c\/p\u003e\u003ctable border=\"1\" cellspacing=\"0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\" width=\"161\"\u003e\u003cp align=\"center\"\u003e\u003cspan style=\"font-family: 'times new roman', times; font-size: small;\"\u003eModel\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"199\"\u003e\u003cp align=\"center\"\u003e\u003cspan style=\"font-family: 'times new roman', times; font-size: small;\"\u003ePR320AP\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"178\"\u003e\u003cp align=\"center\"\u003e\u003cspan style=\"font-family: 'times new roman', times; font-size: small;\"\u003ePR320BP\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"197\"\u003e\u003cp align=\"center\"\u003e\u003cspan style=\"font-family: 'times new roman', times; font-size: small;\"\u003ePR320CP\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"161\"\u003e\u003cp align=\"center\"\u003e\u003cspan style=\"font-family: 'times new roman', times; font-size: small;\"\u003ePR320HP\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\" width=\"161\"\u003e\u003cp align=\"center\"\u003e\u003cspan style=\"font-family: 'times new roman', times; font-size: small;\"\u003eApplicable Scope\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"199\"\u003e\u003cp align=\"center\"\u003e\u003cspan style=\"font-family: 'times new roman', times; font-size: small;\"\u003eS\/R working thermocouple verification\/calibration\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"178\"\u003e\u003cp align=\"center\"\u003e\u003cspan style=\"font-family: 'times new roman', times; font-size: small;\"\u003eSheathed thermocouple calibration\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"197\"\u003e\u003cp align=\"center\"\u003e\u003cspan style=\"font-family: 'times new roman', times; font-size: small;\"\u003eBase metal thermocouple calibration\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"161\"\u003e\u003cp align=\"center\"\u003e\u003cspan style=\"font-family: 'times new roman', times; font-size: small;\"\u003eThermocouple calibration\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\" width=\"161\"\u003e\u003cp align=\"center\"\u003e\u003cspan style=\"font-family: 'times new roman', times; font-size: small;\"\u003eTemperature Range(℃)\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd colspan=\"3\" valign=\"center\" width=\"574\"\u003e\u003cp align=\"center\"\u003e\u003cspan style=\"font-family: 'times new roman', times; font-size: small;\"\u003e300℃～1200℃\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"161\"\u003e\u003cp align=\"center\"\u003e\u003cspan style=\"font-family: 'times new roman', times; font-size: small;\"\u003e300℃～1300℃\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\" width=\"161\"\u003e\u003cp align=\"center\"\u003e\u003cspan style=\"font-family: 'times new roman', times; font-size: small;\"\u003eControl Thermocouple Type\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"199\"\u003e\u003cp align=\"center\"\u003e\u003cspan style=\"font-family: 'times new roman', times; font-size: small;\"\u003eS\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"178\"\u003e\u003cp align=\"center\"\u003e\u003cspan style=\"font-family: 'times new roman', times; font-size: small;\"\u003eN\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"197\"\u003e\u003cp align=\"center\"\u003e\u003cspan style=\"font-family: 'times new roman', times; font-size: small;\"\u003eN\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"161\"\u003e\u003cp align=\"center\"\u003e\u003cspan style=\"font-family: 'times new roman', times; font-size: small;\"\u003eOptional S\/N\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\" width=\"161\"\u003e\u003cp align=\"center\"\u003e\u003cspan style=\"font-family: 'times new roman', times; font-size: small;\"\u003eMatching Isothermal Block\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"199\"\u003e\u003cp align=\"center\"\u003e\u003cspan style=\"font-family: 'times new roman', times; font-size: small;\"\u003eCoaxial Cleaning Ceramic Tube        (Inner Diameter approx. φ20mm)\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"178\"\u003e\u003cp align=\"center\"\u003e\u003cspan style=\"font-family: 'times new roman', times; font-size: small;\"\u003eOptional PR1142A\/B Isothermal Block\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"197\"\u003e\u003cp align=\"center\"\u003e\u003cspan style=\"font-family: 'times new roman', times; font-size: small;\"\u003eOptional PR1145A\/B Isothermal Block\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"161\"\u003e\u003cp align=\"center\"\u003e\u003cspan style=\"font-family: 'times new roman', times; font-size: small;\"\u003eOptional Coaxial Cleaning Ceramic Tube \/ PR1142A \/ PR1145A\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\" width=\"161\"\u003e\u003cp align=\"center\"\u003e\u003cspan style=\"font-family: 'times new roman', times; font-size: small;\"\u003eRegulations\/ Specifications\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"199\"\u003e\u003cp align=\"center\"\u003e\u003cspan style=\"font-family: 'times new roman', times; font-size: small;\"\u003eJJG141-2013\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"178\"\u003e\u003cp align=\"center\"\u003e\u003cspan style=\"font-family: 'times new roman', times; font-size: small;\"\u003eJJF1262-2010\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"197\"\u003e\u003cp align=\"center\"\u003e\u003cspan style=\"font-family: 'times new roman', times; font-size: small;\"\u003eJJF1637-2017\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd rowspan=\"3\" valign=\"center\" width=\"161\"\u003e\u003cp align=\"center\"\u003e\u003cspan style=\"font-family: 'times new roman', times; font-size: small;\"\u003eCustomized products, one type of temperature field accessory can be optionally selected as needed to meet the requirements of corresponding regulations and specifications.\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\" width=\"161\"\u003e\u003cp align=\"center\"\u003e\u003cspan style=\"font-family: 'times new roman', times; font-size: small;\"\u003eTest Temperature Point\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"199\"\u003e\u003cp align=\"center\"\u003e\u003cspan style=\"font-family: 'times new roman', times; font-size: small;\"\u003e420℃, 1000℃, 1085℃\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"178\"\u003e\u003cp align=\"center\"\u003e\u003cspan style=\"font-family: 'times new roman', times; font-size: small;\"\u003e400℃, 1000℃\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"197\"\u003e\u003cp align=\"center\"\u003e\u003cspan style=\"font-family: 'times new roman', times; font-size: small;\"\u003e400℃, 1000℃\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\" width=\"161\"\u003e\u003cp align=\"center\"\u003e\u003cspan style=\"font-family: 'times new roman', times; font-size: small;\"\u003eTemperature Field Specification\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"199\"\u003e\u003cp align=\"center\"\u003e\u003cspan style=\"font-family: 'times new roman', times; font-size: small;\"\u003eThe maximum temperature point inside the furnace deviates from the geometric center of the furnace by no more than 20mm, and within ±20mm of the maximum temperature point, there is a uniform temperature field with a temperature gradient ≤ 0.4 ℃\/10mm.\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"178\"\u003e\u003cp align=\"center\"\u003e\u003cspan style=\"font-family: 'times new roman', times; font-size: small;\"\u003eWithin 30mm axially from the bottom of the hole, the temperature difference shall not exceed 0.5℃; the absolute value of the temperature difference between any holes in the same cross-section at the bottom of the hole shall ≤ 0.25℃.\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"197\"\u003e\u003cp align=\"center\"\u003e\u003cspan style=\"font-family: 'times new roman', times; font-size: small;\"\u003eWithin the axial 30mm of the effective working area, the absolute value of the temperature difference between any two points shall ≤0.5℃; within the radial radius of not less than 14mm, the absolute value of the temperature difference between any two points on the same cross-section shall ≤0.25℃.\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cspan style=\"font-family: 'times new roman', times; font-size: small;\"\u003e\u003cb\u003e \u003c\/b\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"font-family: 'times new roman', times; font-size: small;\"\u003e\u003cb\u003eIsothermal Block \u003c\/b\u003e\u003cb\u003eBasic \u003c\/b\u003e\u003cb\u003eP\u003c\/b\u003e\u003cb\u003earameters\u003c\/b\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/span\u003e\u003c\/p\u003e\u003ctable border=\"1\" cellspacing=\"0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\" width=\"128\"\u003e\u003cp align=\"center\"\u003e\u003cspan style=\"font-family: 'times new roman', times; font-size: small;\"\u003eModel\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"164\"\u003e\u003cp align=\"center\"\u003e\u003cspan style=\"font-family: 'times new roman', times; font-size: small;\"\u003ePR1142A\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"187\"\u003e\u003cp align=\"center\"\u003e\u003cspan style=\"font-family: 'times new roman', times; font-size: small;\"\u003ePR1142B\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"160\"\u003e\u003cp align=\"center\"\u003e\u003cspan style=\"font-family: 'times new roman', times; font-size: small;\"\u003ePR1145A\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"183\"\u003e\u003cp align=\"center\"\u003e\u003cspan style=\"font-family: 'times new roman', times; font-size: small;\"\u003ePR1145B\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\" width=\"128\"\u003e\u003cp align=\"center\"\u003e\u003cspan style=\"font-family: 'times new roman', times; font-size: small;\"\u003eMaterial\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"164\"\u003e\u003cp align=\"center\"\u003e\u003cspan style=\"font-family: 'times new roman', times; font-size: small;\"\u003eNickel-based alloy\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"187\"\u003e\u003cp align=\"center\"\u003e\u003cspan style=\"font-family: 'times new roman', times; font-size: small;\"\u003eHigh-temperature alloy\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"160\"\u003e\u003cp align=\"center\"\u003e\u003cspan style=\"font-family: 'times new roman', times; font-size: small;\"\u003eNickel-based alloy\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"183\"\u003e\u003cp align=\"center\"\u003e\u003cspan style=\"font-family: 'times new roman', times; font-size: small;\"\u003eHigh-temperature alloy\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\" width=\"128\"\u003e\u003cp align=\"center\"\u003e\u003cspan style=\"font-family: 'times new roman', times; font-size: small;\"\u003eTemperature resistance\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"164\"\u003e\u003cp align=\"center\"\u003e\u003cspan style=\"font-family: 'times new roman', times; font-size: small;\"\u003e1300℃\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"187\"\u003e\u003cp align=\"center\"\u003e\u003cspan style=\"font-family: 'times new roman', times; font-size: small;\"\u003e1100℃\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"160\"\u003e\u003cp align=\"center\"\u003e\u003cspan style=\"font-family: 'times new roman', times; font-size: small;\"\u003e1300℃\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"183\"\u003e\u003cp align=\"center\"\u003e\u003cspan style=\"font-family: 'times new roman', times; font-size: small;\"\u003e1100℃\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\" width=\"128\"\u003e\u003cp align=\"center\"\u003e\u003cspan style=\"font-family: 'times new roman', times; font-size: small;\"\u003eLength\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" valign=\"center\" width=\"352\"\u003e\u003cp align=\"center\"\u003e\u003cspan style=\"font-family: 'times new roman', times; font-size: small;\"\u003e115mm\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" valign=\"center\" width=\"344\"\u003e\u003cp align=\"center\"\u003e\u003cspan style=\"font-family: 'times new roman', times; font-size: small;\"\u003e154mm\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\" width=\"128\"\u003e\u003cp align=\"center\"\u003e\u003cspan style=\"font-family: 'times new roman', times; font-size: small;\"\u003eInsertion depth\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" valign=\"center\" width=\"352\"\u003e\u003cp align=\"center\"\u003e\u003cspan style=\"font-family: 'times new roman', times; font-size: small;\"\u003e90mm\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" valign=\"center\" width=\"344\"\u003e\u003cp align=\"center\"\u003e\u003cspan style=\"font-family: 'times new roman', times; font-size: small;\"\u003e135mm\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\" width=\"128\"\u003e\u003cp align=\"center\"\u003e\u003cspan style=\"font-family: 'times new roman', times; font-size: small;\"\u003eOpening\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" valign=\"center\" width=\"352\"\u003e\u003cp align=\"center\"\u003e\u003cspan style=\"font-family: 'times new roman', times; font-size: small;\"\u003eφ8mm×7 pcs\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" valign=\"center\" width=\"344\"\u003e\u003cp align=\"center\"\u003e\u003cspan style=\"font-family: 'times new roman', times; font-size: small;\"\u003eφ28mm\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c!----\u003e\u003cdiv class=\"clear\"\u003e\u003c\/div\u003e","brand":"Warehouse","offers":[{"title":"Default Title","offer_id":53792151961784,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/7224\/3128\/files\/PR320-11.jpg?v=1784607290"},{"product_id":"pr330-thermocouple-calibration-furnace-with-multiple-calorifiers-panran","title":"Factory source Temp Transmitter Calibration - PR330 Thermocouple Calibration Furnace with Multiple Calorifiers","description":"We've been committed to offering easy,time-saving and money-saving one-stop purchasing service of consumer for \u003ca href=\"https:\/\/www.panrancalibration.com\/water-triple-point-cells\/\" title=\"Water Triple Point Cells\"\u003eWater Triple Point Cells\u003c\/a\u003e, \u003ca href=\"https:\/\/www.panrancalibration.com\/digital-pressure-gauges\/\" title=\"Digital Pressure Gauges\"\u003eDigital Pressure Gauges\u003c\/a\u003e, \u003ca href=\"https:\/\/www.panrancalibration.com\/multifunction-reference-thermometer-readout\/\" title=\"Multifunction Reference Thermometer Readout\"\u003eMultifunction Reference Thermometer Readout\u003c\/a\u003e, It is our great honor to meet your demands.We sincerely hope we can cooperate with you in the near future.                            Factory source Temp Transmitter Calibration - PR330 Thermocouple Calibration Furnace with Multiple Calorifiers – Panran              Detail: \u003cbr\u003e\u003cbr\u003e\u003ch6\u003eOverview\u003c\/h6\u003e\u003cp\u003eThe verification furnace or calibration furnace isan important part of the medium and high temperature traceability system. In general,the traditional verification furnace orcalibration furnace is a horizontal electric furnace with simple structure. The temperature uniformity of the effective working area of the furnace can not be well controlled, and the temperature uniformity of the furnace is prone to deviation after the furnace has been used for a long time.Even if the temperatureuniformityof thefurnace is improved to a certain extent by adding metal thermostatic block, its overall technical performance is still not ideal, which is the main source of uncertainty in the process of thermocouple verification and calibration.Therefore, the traditional verification furnaceor calibration furnace cannot meet the requirements of high-precision temperature traceability in terms of structure. PR330 series calibration furnace with multiple calorifiersadopts a subversive design scheme from the internal structure to the control method, and has made a qualitative leap in key technical parameters.\u003c\/p\u003e\u003cp\u003ePR330 series calibration furnace with multiple calorifiers adoptsinnovative technologies such as controlling with multiple calorifiers, DC heating, load balancing, active heat dissipation, and embedded temperature control sensor to extend its working temperature to 100°C~1300°C. With excellent temperature uniformity and temperature stability covering the entire temperature range, the calibration furnacegreatly reduces the uncertainty in the temperature traceability process. In addition, thecalibration furnace possessespowerful human interface function, communication function, and many humanized designs including front and rear dual display screens and hidden scales.\u003c\/p\u003e\u003ch6\u003eFeatures\u003c\/h6\u003e\u003cp\u003e\u003cspan\u003e■ Characteristics of wide temperature uniformity over the entire temperature range\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003eAdoptingtheheating technologywith multiple calorifiers, the power distribution ratio of different parts of the furnace body heating cavity can be calculated in real time according to the current set temperature and heat dissipation conditions, and the ideal temperature uniformity can be achieved at any temperature point without the thermostatic block.\u003c\/p\u003e\u003cp\u003e\u003cspan\u003e■ Wider working temperature range\u003c\/span\u003eWith many new designs in the furnace structure and materials, the working temperature range of the calibration furnace is extended to 100 ℃ ~ 1300 ℃. The calibration furnace can be operated at 1300℃ for a short time or 1250℃ for a long time. The minimum control temperature can be as low as 100 ℃, which further widens the temperature calibration range of thermocouple.\u003c\/p\u003e\u003cp\u003e\u003cspan\u003e■ The temperature stability is better than 0.15 ℃ \/ 10min\u003c\/span\u003eIntegrated new generation PR2601 master controller of PANRAN, with 0.01 level of electrical measurement accuracy, and according to the control requirements of the calibration furnace, the calibration furnace has made targeted optimizations in terms of measurement speed, reading noise, control logic. And its full-range temperature stability is better than 0.15℃\/10min.\u003c\/p\u003e\u003cp\u003e\u003cspan\u003e■ Embedded temperature control thermocouple\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003eIn order to make the process of placing the calibrated sensor more convenient, a detachable temperature control thermocouple is embedded in the inner wall of the heating chamber, which will neither affect the insertion of other sensors nor adversely affect the temperature control process.\u003c\/p\u003e\u003cp\u003e\u003cspan\u003e■ High security\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003eThe power components of PR330 series multi-zone temperature calibration furnaces adopt full DC drive, which can avoid the disturbance caused by electric leakage at high temperature and other high voltage safety hazards from the source. The shell has an independent heat dissipation air duct, which can effectively reduce the temperature of the furnace surface when working at high temperature and avoid scalding caused by misoperation.\u003c\/p\u003e\u003cp\u003e\u003cspan\u003e■ Load balancing function\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003eBy adding an extra thermocouple to monitor the change of axial temperature uniformity in the heating chamber in real time, PR330 series multi-zone temperature calibration furnaces can adjust the power distribution ratio in real time to offset the influence of load insertion and maintain the optimal axial temperature uniformity, so as to meet the higher requirements of calibration.\u003c\/p\u003e\u003cp\u003e\u003cspan\u003e■ Powerful software and hardware function\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003eThe front touch screen can display general measurement and control parameters, and can perform operations such as timing switch, temperature stability setting, and WIFI setting. In order to facilitate the observation of real-time temperature from multiple angles, a secondary display with stability indication is also installed at the rear of the calibration furnace.\u003c\/p\u003e\u003cp\u003e\u003cimg alt=\"\" src=\"\/\/www.panrancalibration.com\/uploads\/RnTsswQ7nH.png\" width=\"665\" height=\"261\"\u003e\u003c\/p\u003e\u003cp\u003eSpecifications\u003c\/p\u003e\u003cp\u003e\u003cimg alt=\"\" src=\"\/\/www.panrancalibration.com\/uploads\/eMTePaXksY.png\"\u003e\u003c\/p\u003e\u003cp\u003eProduct Model\u003c\/p\u003e\u003cp\u003e\u003cimg alt=\"\" src=\"\/\/www.panrancalibration.com\/uploads\/60d3ee66d2cb1.png\"\u003e\u003c\/p\u003e\u003c!----\u003e\u003cdiv class=\"clear\"\u003e\u003c\/div\u003e                                          Product detail pictures:\u003cbr\u003e\u003cbr\u003e\u003ccenter\u003e\u003ca class=\"lightbox\" href=\"https:\/\/cdn.globalso.com\/panrancalibration\/c96b5ccf1.jpg\"\u003e\u003cimg src=\"https:\/\/cdn.globalso.com\/panrancalibration\/c96b5ccf1.jpg\" alt=\"Factory source Temp Transmitter Calibration - PR330 Thermocouple Calibration Furnace with Multiple Calorifiers – Panran detail pictures\"\u003e\u003c\/a\u003e\u003c\/center\u003e\u003cbr\u003e                                                        Related Product Guide:\u003cbr\u003e                                          We've our have sales staff, style and design staff, technical crew, QC team and package workforce. We've strict excellent control procedures for each system. Also, all of our workers are experienced in printing field for              Factory source Temp Transmitter Calibration - PR330 Thermocouple Calibration Furnace with Multiple Calorifiers – Panran              , The product will supply to all over the world, such as: Greenland, Sierra Leone, Singapore, With strong technical strength and advanced production equipment, and SMS people purposefully , professional, dedicated spirit of enterprise. Enterprises took the lead through the ISO 9001:2008 international quality management system certification, CE certification EU ; CCC.SGS.CQC other related product certification. We look forward to reactivating our company connection.","brand":"Warehouse","offers":[{"title":"Default Title","offer_id":53792152617144,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/7224\/3128\/files\/c96b5ccf1.jpg?v=1784607306"}],"url":"https:\/\/temptechsupply.com.au\/collections\/calibration-furnaces.oembed","provider":"TechTemp Supply","version":"1.0","type":"link"}