{"product_id":"pr565-infrared-forehead-thermometer-blackbody-radiation-calibration-bath","title":"PR565 Infrared Forehead Thermometer Blackbody Radiation Calibration Bath","description":"\u003ch3\u003eProduct video\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cspan\u003e\u003cstrong\u003ePR565 Infrared Forehead Thermometer Blackbody Radiation Calibration Bath\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eOverview:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003ePanran Measurement \u0026amp; Control provides a comprehensive infrared ear thermometer and infrared forehead thermometer calibration solution. The infrared ear thermometer and forehead thermometer calibration system consists of three parts:\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003ePart1. Black-body radiation cavity, high-emissivity black-body radiation cavity is a key component required for the calibration of infrared ear thermometers and forehead thermometers. Its structure and the quality of the internal coating have a significant impact on the calibration results.\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e \u003c\/p\u003e\u003cp\u003e\u003cspan\u003ePart2. Temperature source–Liquid constant temperature device, used to place and immerse the black body radiation cavity, so that each surface of the radiation cavity has excellent temperature uniformity and temperature fluctuation.\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e \u003c\/p\u003e\u003cp\u003e\u003cspan\u003ePart3. Temperature standard, used to measure the temperature of the medium in the liquid thermostat.\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e \u003c\/p\u003e\u003cp\u003e\u003cstrong\u003e\u003cspan\u003ePart1. Black-body radiation cavity\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eThere are two types of black body radiation chambers, which are used to calibrate infrared ear thermometers and infrared forehead thermometers. The black body cavity is gold-plated on the outside and has a high-emissivity coating inside. Requirements to meet the calibration requirements of most infrared ear thermometers and infrared forehead thermometers.\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e \u003c\/p\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd width=\"164\"\u003e\u003cspan\u003eItem\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"261\"\u003e\n\u003cspan\u003eHC1656012\u003c\/span\u003e\u003cspan\u003eFor infrared ear thermometer calibration\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"291\"\u003e\n\u003cspan\u003eHC1686045\u003c\/span\u003e\u003cspan\u003eFor infrared forehead thermometer calibration\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"164\"\u003e\n\u003cspan\u003eEmissivity\u003c\/span\u003e\u003cspan\u003e（\u003c\/span\u003e\u003cspan\u003e8\u003c\/span\u003e\u003cspan\u003e～\u003c\/span\u003e\u003cspan\u003e14 μm wavelength\u003c\/span\u003e\u003cspan\u003e）\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"261\"\u003e\n\u003cspan\u003e≥\u003c\/span\u003e\u003cspan\u003e0.999\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"291\"\u003e\n\u003cspan\u003e≥\u003c\/span\u003e\u003cspan\u003e0.997\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"164\"\u003e\u003cspan\u003eDiameter of the hole\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd width=\"261\"\u003e\u003cspan\u003e10mm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"291\"\u003e\u003cspan\u003e60mm \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"164\"\u003e\u003cspan\u003eMax immersion depth\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd width=\"261\"\u003e\u003cspan\u003e150mm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"291\"\u003e\u003cspan\u003e300mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"164\"\u003e\u003cspan\u003eFlange diameter\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" width=\"552\"\u003e\u003cspan\u003e130mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e \u003c\/p\u003e\u003cp\u003e\u003cimg title=\"1629188853822904.jpg\" alt=\"4980260929558967_2021_08_84287bb6cd3bfaeee7405b0f652d0c17.jpg\" src=\"\/\/www.panrancalibration.com\/uploads\/1629188853822904.jpg\" width=\"341\" height=\"320\"\u003e\u003cimg title=\"1584690354355785.jpg\" alt=\"微信图片_20200319135748.jpg\" src=\"\/\/www.panrancalibration.com\/uploads\/1584690354355785.jpg\" width=\"367\" height=\"319\"\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003e\u003cspan\u003ePart2. Temperature source–the liquid constant temperature device\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eThe liquid constant temperature device can choose two types of products, the PR560B infrared thermometer calibration thermostat or the PR532-N10 refrigeration thermostat, both of which have excellent temperature stability and temperature uniformity. Among them, the volume of the thermostat used for the calibration of the PR560B infrared thermometer is only 1\/2 of that of an ordinary thermostat, which is convenient to move, transport, or transform it into a vehicle-mounted calibration device.\u003c\/span\u003e\u003c\/p\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd width=\"125\"\u003e\u003cspan\u003eItems\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"192\"\u003e\n\u003cspan\u003ePR560B\u003c\/span\u003e\u003cspan\u003einfrared thermometer calibration thermostatic bath\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"189\"\u003e\n\u003cspan\u003ePR532-N10\u003c\/span\u003e\u003cspan\u003eCooling bath\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"178\"\u003e\u003cspan\u003eRemarks\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"125\"\u003e\u003cspan\u003eTemperature range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd width=\"192\"\u003e\n\u003cspan\u003e10\u003c\/span\u003e\u003cspan\u003e～\u003c\/span\u003e\u003cspan\u003e90℃\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"189\"\u003e\n\u003cspan\u003e-10\u003c\/span\u003e\u003cspan\u003e～\u003c\/span\u003e\u003cspan\u003e150℃\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"178\"\u003e\n\u003cspan\u003eEnvironment temp. 5\u003c\/span\u003e\u003cspan\u003e℃～\u003c\/span\u003e\u003cspan\u003e35\u003c\/span\u003e\u003cspan\u003e℃\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"125\"\u003e\u003cspan\u003eAccuracy\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd width=\"192\"\u003e\n\u003cspan\u003e36\u003c\/span\u003e\u003cspan\u003e℃，≤\u003c\/span\u003e\u003cspan\u003e0.07\u003c\/span\u003e\u003cspan\u003e℃\u003c\/span\u003e\u003cspan\u003eFull range\u003c\/span\u003e\u003cspan\u003e，≤\u003c\/span\u003e\u003cspan\u003e0.1\u003c\/span\u003e\u003cspan\u003e℃\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"189\"\u003e\n\u003cspan\u003e0.1\u003c\/span\u003e\u003cspan\u003e℃\u003c\/span\u003e\u003cspan\u003e+0.1%RD\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"178\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"125\"\u003e\u003cspan\u003eWork medium\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd width=\"192\"\u003e\u003cspan\u003eDistilled water\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"189\"\u003e\u003cspan\u003eantifreeze\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"178\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"125\"\u003e\u003cspan\u003eResolution\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" width=\"381\"\u003e\n\u003cspan\u003e0.001\u003c\/span\u003e\u003cspan\u003e℃\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"178\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"125\"\u003e\u003cspan\u003eTemperature uniformity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" width=\"381\"\u003e\n\u003cspan\u003e0.01\u003c\/span\u003e\u003cspan\u003e℃\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"178\"\u003e\n\u003cspan\u003eFull range\u003c\/span\u003e\u003cspan\u003eFrom 40mm from the bottom\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"125\"\u003e\u003cspan\u003eTemperature stability\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" width=\"381\"\u003e\n\u003cspan\u003e≤\u003c\/span\u003e\u003cspan\u003e0.005\u003c\/span\u003e\u003cspan\u003e℃\u003c\/span\u003e\u003cspan\u003e\/1min \u003c\/span\u003e\u003cspan\u003e≤\u003c\/span\u003e\u003cspan\u003e0.01\u003c\/span\u003e\u003cspan\u003e℃\u003c\/span\u003e\u003cspan\u003e\/10min\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"178\"\u003e\u003cspan\u003e20 minutes after reaching the set temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"125\"\u003e\u003cspan\u003ePower supply\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" width=\"381\"\u003e\n\u003cspan\u003e220VAC\u003c\/span\u003e\u003cspan\u003e，\u003c\/span\u003e\u003cspan\u003e50Hz\u003c\/span\u003e\u003cspan\u003e，\u003c\/span\u003e\u003cspan\u003e2KVA\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"178\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"125\"\u003e\u003cspan\u003eDimension\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd width=\"192\"\u003e\n\u003cspan\u003e800mm\u003c\/span\u003e\u003cspan\u003e×\u003c\/span\u003e\u003cspan\u003e426mm\u003c\/span\u003e\u003cspan\u003e×\u003c\/span\u003e\u003cspan\u003e500mm\u003c\/span\u003e\u003cspan\u003e（\u003c\/span\u003e\u003cspan\u003eH\u003c\/span\u003e\u003cspan\u003e×\u003c\/span\u003e\u003cspan\u003eH\u003c\/span\u003e\u003cspan\u003e×\u003c\/span\u003e\u003cspan\u003eW\u003c\/span\u003e\u003cspan\u003e）\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"189\"\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"178\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"125\"\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd width=\"192\"\u003e\u003cspan\u003e60KG\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"189\"\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"178\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cspan\u003eNote: If the customer already has a constant temperature device that can meet the calibration requirements, it can also be used directly.\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e \u003c\/p\u003e\u003cp\u003e\u003cimg title=\"1584690535956489.jpg\" alt=\"\" src=\"\/\/www.panrancalibration.com\/uploads\/1584690535956489.jpg\" width=\"697\" height=\"155\"\u003e\u003c\/p\u003e\u003cp\u003e\u003cimg title=\"1584690536167817.jpg\" alt=\"\" src=\"\/\/www.panrancalibration.com\/uploads\/1584690536167817.jpg\" width=\"306\" height=\"215\"\u003e\u003cimg title=\"1584690536666855.jpg\" alt=\"\" src=\"\/\/www.panrancalibration.com\/uploads\/1584690536666855.jpg\" width=\"482\" height=\"203\"\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003e\u003cspan\u003ePart3. Temperature standard\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eOption 1:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e In response to the calibration requirements of infrared thermometers, Panran introduced the PR712A standard digital thermometer, with an annual change of better than 0.01 ° C over the full range. Compared with the PR710 and PR711 precision digital thermometers of the same series, it has a better built-in reference resistance, better temperature coefficient and long-term stability. At an ambient temperature of 10 to 35 ° C, its typical temperature coefficient is only 0.5 ppm \/ ° C.\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e \u003c\/p\u003e\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eOption 2: \u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003eTraditional electrical measurement equipment + standard platinum resistance. The electrical measurement equipment in this solution can be configured with PR293 series nanovolt micro-ohm thermometer or PR291 series micro-ohm thermometer. Both series of products can meet the requirements of electrical thermometers related to infrared thermometers.\u003c\/span\u003e\u003c\/p\u003e\u003ctable style=\"width: 666px;\"\u003e\u003ctbody\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd width=\"114\"\u003e\u003cspan\u003eItems\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd width=\"132\"\u003e\n\u003cspan\u003ePR712A \u003c\/span\u003e\u003cspan\u003eStandard digital thermometer\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd width=\"137\"\u003e\n\u003cspan\u003ePR293 series\u003c\/span\u003e\u003cspan\u003eNanovolt microohm thermometer\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd width=\"132\"\u003e\n\u003cspan\u003ePR291 series\u003c\/span\u003e\u003cspan\u003eMicroohm thermometer\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd width=\"100\"\u003e\u003cspan\u003eRemarks\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"114\"\u003e\u003cspan\u003eDescription\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd width=\"132\"\u003e\n\u003cspan\u003eHigh-precision integrated thermometer\u003c\/span\u003e\u003cspan\u003e，\u003c\/span\u003e\u003cspan\u003etemp. sensor is wound typePT100\u003c\/span\u003e\u003cspan\u003e，\u003c\/span\u003e\u003cspan\u003esensor\u003c\/span\u003e\u003cspan\u003eφ\u003c\/span\u003e\u003cspan\u003e5*400mm\u003c\/span\u003e\u003cspan\u003e。\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd width=\"137\"\u003e\u003cspan\u003eFull-featured thermocouple and platinum resistance thermometer\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd width=\"132\"\u003e\u003cspan\u003eHigh-precision platinum resistance thermometer\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd width=\"100\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"114\"\u003e\u003cspan\u003eChannel No.\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd width=\"132\"\u003e\u003cspan\u003e1\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd width=\"137\"\u003e\n\u003cspan\u003e2\u003c\/span\u003e\u003cspan\u003e或\u003c\/span\u003e\u003cspan\u003e5\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd width=\"132\"\u003e\u003cspan\u003e2\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd width=\"100\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"114\"\u003e\u003cspan\u003eAccuracy\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd width=\"132\"\u003e\n\u003cspan\u003e0.01\u003c\/span\u003e\u003cspan\u003e℃\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\" width=\"269\"\u003e\n\u003cspan\u003eElectricity\u003c\/span\u003e\u003cspan\u003e：\u003c\/span\u003e\u003cspan\u003e20ppm(RD)+2.5ppm(FS)\u003c\/span\u003e\u003cspan\u003eTemperature\u003c\/span\u003e\u003cspan\u003e：\u003c\/span\u003e\u003cspan\u003e36\u003c\/span\u003e\u003cspan\u003e℃，≤\u003c\/span\u003e\u003cspan\u003e0.008\u003c\/span\u003e\u003cspan\u003e℃\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd rowspan=\"3\" width=\"100\"\u003e\u003cspan\u003eThe PR291 and PR293 thermometers use standard platinum resistance measurement functions.\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"114\"\u003e\u003cspan\u003eResolution\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd width=\"132\"\u003e\n\u003cspan\u003e0.001\u003c\/span\u003e\u003cspan\u003e℃\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\" width=\"269\"\u003e\n\u003cspan\u003e0.0001\u003c\/span\u003e\u003cspan\u003e℃\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"114\"\u003e\u003cspan\u003eTemperature range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd width=\"132\"\u003e\n\u003cspan\u003e-5\u003c\/span\u003e\u003cspan\u003e℃～\u003c\/span\u003e\u003cspan\u003e50\u003c\/span\u003e\u003cspan\u003e℃\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\" width=\"269\"\u003e\n\u003cspan\u003e-200\u003c\/span\u003e\u003cspan\u003e℃～\u003c\/span\u003e\u003cspan\u003e660\u003c\/span\u003e\u003cspan\u003e℃\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"114\"\u003e\u003cspan\u003eCommunication\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd width=\"132\"\u003e\n\u003cspan\u003e2.4G\u003c\/span\u003e\u003cspan\u003e无线\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\" width=\"269\"\u003e\u003cspan\u003eRS485\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd width=\"100\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"114\"\u003e\u003cspan\u003eBattery power duration\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd width=\"132\"\u003e\u003cspan\u003e\u0026gt;1400h\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" width=\"269\"\u003e\n\u003cspan\u003e＞\u003c\/span\u003e\u003cspan\u003e6h\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd width=\"100\"\u003e\u003cspan\u003ePR712Apower is AAAbattery\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"114\"\u003e\u003cspan\u003eDimention(Body)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd width=\"132\"\u003e\n\u003cspan\u003e104\u003c\/span\u003e\u003cspan\u003e×\u003c\/span\u003e\u003cspan\u003e64\u003c\/span\u003e\u003cspan\u003e×\u003c\/span\u003e\u003cspan\u003e30mm\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\" width=\"269\"\u003e\n\u003cspan\u003e230\u003c\/span\u003e\u003cspan\u003e×\u003c\/span\u003e\u003cspan\u003e220\u003c\/span\u003e\u003cspan\u003e×\u003c\/span\u003e\u003cspan\u003e112mm\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd width=\"100\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"114\"\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd width=\"132\"\u003e\u003cspan\u003e110g\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" width=\"269\"\u003e\u003cspan\u003e2800g\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd width=\"100\"\u003e\u003cspan\u003eIncluding battery weight\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eApplication:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eThe high precision cooling thermostatic bath is suitable for measuring, biochemical, petroleum, meteorology, energy, environmental protection, medicine and other departments and manufacturers of thermometers, temperature controllers, temperature sensors and other manufacturers to test and calibrate physical parameters. It can also provide constant temperature source for other experimental research work. Example 1. Second-class standard mercury thermometer, Forehead thermometers, Infrared Surface Thermometers, Ear Thermometers, beckman thermometer, industrial platinum thermal resistance, standard copper-constantan thermocouple verification, etc.\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e \u003c\/p\u003e\u003c!----\u003e\u003cdiv class=\"clear\"\u003e\u003c\/div\u003e","brand":"Warehouse","offers":[{"title":"Default Title","offer_id":53792152158392,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/7224\/3128\/files\/29b86907.jpg?v=1784607295","url":"https:\/\/temptechsupply.com.au\/products\/pr565-infrared-forehead-thermometer-blackbody-radiation-calibration-bath","provider":"TechTemp Supply","version":"1.0","type":"link"}