{"product_id":"pr611a-pr613a-multifunctional-dry-block-calibrator","title":"PR611A\/ PR613A Multifunctional Dry Block Calibrator","description":"\u003cp\u003e\u003cstrong\u003eOverview \u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003ePR611A\/PR613A dry block calibrator is a new generation of portable temperature calibration equipment that integrates advanced technologies such as intelligent dual-zone temperature control, automatic temperature calibration, and precision measurement. It has excellent static and dynamic temperature control characteristics, built-in independent full-function temperature measurement channel and standard measurement channel, and can edit complex calibration tasks. The automatic calibration of thermocouples, thermal resistances, temperature switches, and electrical signal output temperature transmitters can be realized without other peripherals, It’s very suitable for industrial field and laboratory use.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eKeywords： \u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eIntelligent dual-zone temperature control\u003c\/p\u003e\u003cp\u003eEditable task mode\u003c\/p\u003e\u003cp\u003eRapid heating and cooling\u003c\/p\u003e\u003cp\u003eElectrical measurement\u003c\/p\u003e\u003cp\u003eHART function\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eAppearance\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003e\u003cimg title=\"1662101801920941.png\" alt=\"72c5593bab2f28678457d59d4dfd399.png\" src=\"\/\/www.panrancalibration.com\/uploads\/1662101801920941.png\"\u003e\u003c\/span\u003e\u003c\/p\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\" width=\"56\"\u003eNO.\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"226\"\u003eName\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"57\"\u003eNO.\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"182\"\u003eName\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\" width=\"56\"\u003e1\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"226\"\u003eWorking cavity\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"57\"\u003e6\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"182\"\u003ePower switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\" width=\"56\"\u003e2\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"226\"\u003eTest terminal area\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"57\"\u003e7\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"182\"\u003eUSB port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\" width=\"56\"\u003e3\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"226\"\u003eExternal reference\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"57\"\u003e8\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"182\"\u003eCommunication port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\" width=\"56\"\u003e4\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"226\"\u003eMini thermocouple socket\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"57\"\u003e9\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"182\"\u003eDisplay screen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\" width=\"56\"\u003e5\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"226\"\u003eExternal power interface\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"57\"\u003e\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"182\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cstrong\u003eI Features\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDual-zone temperature control\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eThe bottom and top of the dry block calibrator heating cavity have two independent temperature control, Combined with temperature coupling control algorithm to ensure the uniformity of temperature field of dry block calibrator in a complex and changing environment.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eRapid heating and cooling\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eThe heat and cooling capacity of the current working condition are adjusted in real time by intelligent control algorithm，while optimizing the control characteristics, the heating and cooling speed can be greatly increased.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFull-featured electrical measurement channel\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eThe full-featured electrical measurement channel is used to measure various types of thermal resistance, thermocouple, temperature transmitter and temperature switch, with a measurement accuracy better than 0.02%.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eReference measurement channel\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eThe standard wire-wound platinum resistance is used as the reference sensor, and it supports multi-point interpolation correction algorithm to obtain better temperature traceability accuracy.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eEditable task mode\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eCan edit and design complex task functions including temperature calibration points, stability criterion, sampling method, delay time and other multiple calibration parameters, so as to realize the automatic calibration process of multiple temperature calibration points.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFully automatic temperature switch calibration\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eWith a settable slope temperature rise and fall and switch value measurement functions, can perform fully automatic temperature switch calibration tasks through simple parameter settings.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSupport HART transmitter calibration\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eWith built-in 250Ω resistance and 24V loop power supply, the HART temperature transmitter can be independently calibrated without other peripherals.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSupports USB storage devices\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eThe calibration data generated after the calibration task is executed will be saved in the internal memory in the format of a CSV file. The data can be viewed on the dry block calibrator or exported to a USB storage device through the USB interface.\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/\/cdn.globalso.com\/panrancalibration\/1672822502994416.png\"\u003e\u003cimg class=\"alignnone size-full wp-image-5012\" alt=\"1672822502994416\" src=\"\/\/cdn.globalso.com\/panrancalibration\/1672822502994416.png\"\u003e\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eII  List of main functions\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/\/cdn.globalso.com\/panrancalibration\/1672823931394184.png\"\u003e\u003cimg class=\"alignnone size-full wp-image-5013\" alt=\"1672823931394184\" src=\"\/\/cdn.globalso.com\/panrancalibration\/1672823931394184.png\"\u003e\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eIII Technical Parameters\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eGeneral parameters\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/\/cdn.globalso.com\/panrancalibration\/1672823226756547.png\"\u003e\u003cimg class=\"alignnone size-full wp-image-5014\" alt=\"1672823226756547\" src=\"\/\/cdn.globalso.com\/panrancalibration\/1672823226756547.png\"\u003e\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eTemperature field parameters\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/\/cdn.globalso.com\/panrancalibration\/1672823207987078.png\"\u003e\u003cimg class=\"alignnone size-full wp-image-5015\" alt=\"1672823207987078\" src=\"\/\/cdn.globalso.com\/panrancalibration\/1672823207987078.png\"\u003e\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eElectrical measurement parameters\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/\/cdn.globalso.com\/panrancalibration\/1672823294104937.png\"\u003e\u003cimg class=\"alignnone size-full wp-image-5016\" alt=\"1672823294104937\" src=\"\/\/cdn.globalso.com\/panrancalibration\/1672823294104937.png\"\u003e\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eThermocouple temperature measurement parameters\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/\/cdn.globalso.com\/panrancalibration\/1672823481137563.png\"\u003e\u003cimg class=\"alignnone size-full wp-image-5017\" alt=\"1672823481137563\" src=\"\/\/cdn.globalso.com\/panrancalibration\/1672823481137563.png\"\u003e\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eThermal resistance temperature measurement parameters\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/\/cdn.globalso.com\/panrancalibration\/1672823450872184.png\"\u003e\u003cimg class=\"alignnone size-full wp-image-5018\" alt=\"1672823450872184\" src=\"\/\/cdn.globalso.com\/panrancalibration\/1672823450872184.png\"\u003e\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e \u003c\/p\u003e\u003c!----\u003e\u003cdiv class=\"clear\"\u003e\u003c\/div\u003e","brand":"Warehouse","offers":[{"title":"Default Title","offer_id":53792151437496,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/7224\/3128\/files\/6d5808dc.jpg?v=1784607278","url":"https:\/\/temptechsupply.com.au\/products\/pr611a-pr613a-multifunctional-dry-block-calibrator","provider":"TechTemp Supply","version":"1.0","type":"link"}