{"product_id":"zrj-23-series-intelligent-thermal-instrument-verification-system","title":"ZRJ-23 Series Intelligent Thermal Instrument Verification System","description":"\u003cp\u003eZRJ series intelligent thermal instrument verification system integrates software, hardware, engineering and service. After more than 30 years of market tests, it has long been at the forefront of the industry in terms of software and hardware level, product quality, after-sales service, and market ownership, and has been widely accepted by customers. It has played an important role in the field of temperature measurement for a long time.\u003c\/p\u003e\u003cp\u003eThe new-generation ZRJ-23 series intelligent thermal instrument verification system is the latest member of the ZRJ series products, which greatly simplifies the composition of the traditional thermocouple and thermal resistance verification systems. The PR160 reference standard scanner with excellent electrical performance is used as the the core, which can be expanded up to 80 sub-channels, can be flexibly combined with various temperature sources to meet the verification\/calibration requirements of various thermocouples, thermal resistances and temperature transmitters. It is not only suitable for new laboratories, but also very suitable for traditional temperature laboratory upgrading their equipment.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eKeywords\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eA new generation of thermocouple, thermal resistance verification system\u003c\/li\u003e\n\u003cli\u003eEnhanced Standard Temperature Control\u003c\/li\u003e\n\u003cli\u003eComposite switch structure\u003c\/li\u003e\n\u003cli\u003eAccuracy better than 40ppm\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eTypical Application\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eUses of Homopolars \u0026amp; Bipolars Comparison Method to Calibrate Thermocouples\u003c\/li\u003e\n\u003cli\u003eVerification\/Calibration of Base Metal Thermocouples\u003c\/li\u003e\n\u003cli\u003eVerification\/Calibration of Platinum Resistance of Various Grades\u003c\/li\u003e\n\u003cli\u003eCalibrating the Integral Temperature Transmitter\u003c\/li\u003e\n\u003cli\u003eCalibrating HART Type Temperature Transmitters\u003c\/li\u003e\n\u003cli\u003eMixed Temperature Sensor Verification\/Calibration\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eMixed Verification\/Calibration of Thermocouple \u0026amp; RTD\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/\/cdn.globalso.com\/panrancalibration\/1672819843707697.png\"\u003e\u003cimg class=\"aligncenter\" alt=\"1672819843707697\" src=\"\/\/cdn.globalso.com\/panrancalibration\/1672819843707697.png\"\u003e\u003c\/a\u003e\u003c\/p\u003e\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eDual Furnace Thermocouple Verification\/Calibration\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/\/cdn.globalso.com\/panrancalibration\/1672804972821049.png\"\u003e\u003cimg class=\"aligncenter\" alt=\"1672804972821049\" src=\"\/\/cdn.globalso.com\/panrancalibration\/1672804972821049.png\"\u003e\u003c\/a\u003e\u003c\/p\u003e\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eGroup Furnace Thermocouple Verification\/Calibration\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/\/cdn.globalso.com\/panrancalibration\/1672805008478295.png\"\u003e\u003cimg class=\"aligncenter\" alt=\"1672805008478295\" src=\"\/\/cdn.globalso.com\/panrancalibration\/1672805008478295.png\"\u003e\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eI- Brand new hardware design\u003c\/strong\u003e\u003cstrong\u003e \u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eThe new-generation ZRJ-23 system is the crystallization of years of technical development. Compared with the traditional thermocouple\/thermal resistance verification system, its scanner structure, bus topology, electrical measurement standard and other key components are all newly designed, rich in functions, novel in structure, and highly expandable.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003e1、Hardware technical features\u003c\/strong\u003e\u003cstrong\u003e \u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eCompact Structure\u003c\/p\u003e\u003cp\u003eThe core control unit integrates a scanner, a thermometer, and a terminal block. It has its own thermometer thermostat, so there is no need to set up a constant temperature room for the electrical standard. Compared with the traditional couple resistance verification system, it has fewer leads, a clearer structure, and less energy. space.\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/\/cdn.globalso.com\/panrancalibration\/1672819723520417.png\"\u003e\u003cimg class=\"aligncenter\" alt=\"1672819723520417\" src=\"\/\/cdn.globalso.com\/panrancalibration\/1672819723520417.png\"\u003e\u003c\/a\u003e\u003c\/p\u003e\u003cp style=\"text-align: center;\"\u003e▲ Core Control Unit\u003c\/p\u003e\u003cp\u003eComposite Scan Switch\u003c\/p\u003e\u003cp\u003eThe composite scan switch has the advantages of high performance and multi-function. The main scan switch is a mechanical switch made of tellurium copper with silver coating, which has extremely low contact potential and contact resistance, the function switch adopts low-potential relay, which can be independently configured with up to 10 switch combinations for various calibration needs. (Invention Patent: ZL 2016 1 0001918.7)\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/\/cdn.globalso.com\/panrancalibration\/1672805444173713.png\"\u003e\u003cimg class=\"aligncenter\" alt=\"1672805444173713\" src=\"\/\/cdn.globalso.com\/panrancalibration\/1672805444173713.png\"\u003e\u003c\/a\u003e\u003c\/p\u003e\u003cp style=\"text-align: center;\"\u003e▲ Composite Scan Switch\u003c\/p\u003e\u003cp\u003eEnhanced Standard Temperature Control\u003c\/p\u003e\u003col\u003e\n\u003cli\u003eThe scanner integrates a dual-channel temperature control unit with voltage compensation function. It can use the temperature value of the standard and the tested channel to perform hybrid constant temperature control through the decoupling algorithm. Compared with the traditional temperature control method, it can greatly improve the temperature control accuracy and effectively shorten the waiting time for thermal equilibrium at constant temperature.\u003c\/li\u003e\n\u003cli\u003eSupports Homopolars Comparison Method to Calibrate Thermocouples\u003c\/li\u003e\n\u003cli\u003eThrough the logical cooperation of PR160 series scanner and PR293A thermometer, 12 or 16 channel noble metal thermocouple calibration can be performed using the homopolars comparison method.\u003c\/li\u003e\n\u003c\/ol\u003e\u003cp\u003eProfessional and Flexible CJ Options\u003c\/p\u003e\u003cp\u003eOptional freezing point compensation, external CJ, Mini thermocouple plug or smart CJ. The smart CJ has a built-in temperature sensor with correction value. It is made of tellurium copper and can be split into two independent clamps. The unique design of the clip can easily bite together conventional wires and nuts, so that the processing process of the CJ reference terminal is no longer cumbersome. (Invention patent: ZL 2015 1 0534149.2)\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/\/cdn.globalso.com\/panrancalibration\/1672819748557139.png\"\u003e\u003cimg class=\"aligncenter\" alt=\"1672819748557139\" src=\"\/\/cdn.globalso.com\/panrancalibration\/1672819748557139.png\"\u003e\u003c\/a\u003e\u003c\/p\u003e\u003cp style=\"text-align: center;\"\u003e▲ Optional Smart CJ Reference\u003c\/p\u003e\u003cp\u003eOn-resistance Symmetrical Characteristics\u003c\/p\u003e\u003cp\u003eCan connect multiple three-wire secondary instruments for batch calibration without additional wire conversion.\u003c\/p\u003e\u003cp\u003eProfessional Transmitter Calibration Mode.\u003c\/p\u003e\u003cp\u003eBuilt-in 24V output, supports batch calibration of voltage-type or current-type integrated temperature transmitters. For the unique design of the current type transmitter, the patrol inspection of the current signal can be carried out without cutting off the current loop.\u003c\/p\u003e\u003cp\u003ePress-Type Multifunctional Tellurium Copper Terminal.\u003c\/p\u003e\u003cp\u003eUsing tellurium copper gold plating process, it has excellent electrical connection performance and provides a variety of wire connection methods.\u003c\/p\u003e\u003cp\u003eRich Temperature Measurement Functions.\u003c\/p\u003e\u003cp\u003eThe electrical measuring standard adopts PR291 and PR293 series thermometers, which have rich temperature measurement functions, 40ppm electrical measurement accuracy, and 2 or 5 measurement channels.\u003c\/p\u003e\u003cp\u003eThermometer Thermostat with constant temperature heating and cooling capability.\u003c\/p\u003e\u003cp\u003eIn order to meet the requirements of various regulations and specifications for the ambient temperature of the electrical measuring standard, the thermometer thermostat is integrated, which has constant temperature heating and cooling capabilities, and can provide a stable temperature of 23 ℃ for the thermometer in the external environment of -10~30 ℃. room temperature environment.\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/\/cdn.globalso.com\/panrancalibration\/1672805645651982.png\"\u003e\u003cimg alt=\"1672805645651982\" src=\"\/\/cdn.globalso.com\/panrancalibration\/1672805645651982.png\"\u003e\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003e2、 Scanner function\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/\/cdn.globalso.com\/panrancalibration\/1672817266608947.png\"\u003e\u003cimg alt=\"1672817266608947\" src=\"\/\/cdn.globalso.com\/panrancalibration\/1672817266608947.png\"\u003e\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003e3、Channel function\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/\/cdn.globalso.com\/panrancalibration\/1672816975170924.png\"\u003e\u003cimg alt=\"1672816975170924\" src=\"\/\/cdn.globalso.com\/panrancalibration\/1672816975170924.png\"\u003e\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eII - Excellent Software Platform\u003c\/strong\u003e\u003cstrong\u003e \u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eThe relevant supporting software of ZRJ series products has obvious comprehensive advantages. It is not only a tool software that can be used for verification or calibration according to the current regulations, but a software platform composed of multiple  powerful expertise temperature measurement software. Its professionalism, ease of use, and operability have been recognized by many customers in the industry, which can provide a great convenience for customers’ daily verification\/calibration work.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003e1、Software Technical Features\u003c\/strong\u003e\u003cstrong\u003e \u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eProfessional Uncertainty Analysis Function\u003c\/p\u003e\u003cp\u003eThe evaluation software can automatically calculate the uncertainty values, degrees of freedom and expanded uncertainty of each standard, and generate a summary table of uncertainty components and an uncertainty evaluation and analysis report. After the verification is completed, the actual expanded uncertainty of the verification result can be automatically calculated, and a summary table of the uncertainty components of each verification point can be automatically drawn.\u003c\/p\u003e\u003cp\u003eNew Constant Temperature Assessment Algorithm.\u003c\/p\u003e\u003cp\u003eThe new algorithm takes the uncertainty analysis as a reference,  according to the repeatability ratio of the calibrated thermocouple’s reasonable measurement data, the repeatability standard deviation that the calculation system should achieve is used as the basis for judging the timing of data collection, which is very suitable for the case of thick thermocouples or multiple calibrated thermocouples.\u003c\/p\u003e\u003cp\u003eComprehensive Data Analysis Capabilities.\u003c\/p\u003e\u003cp\u003eDuring the verification or calibration process, the system will automatically perform statistics and analysis on real-time data and provide contents including temperature deviation, measurement repeatability, fluctuation level, external interference, and adaptability of adjustment parameters.\u003c\/p\u003e\u003cp\u003eProfessional and Rich Report Output Function.\u003c\/p\u003e\u003cp\u003eThe software can automatically generate verification records in Chinese and English, support digital signatures, and can provide users with certificates in various formats such as verification, calibration, and customization.\u003c\/p\u003e\u003cp\u003eSmart Metrology APP.\u003c\/p\u003e\u003cp\u003eThe Panran Smart Metrology APP can remotely operate or view the current task, upload the operating data to the cloud server in real time, and use smart cameras to monitor the scene visually. In addition, the APP also integrates a wealth of tool software, which is convenient for users to perform operations such as temperature conversion and regulation specification query.\u003c\/p\u003e\u003cp\u003eMixed Verification Function.\u003c\/p\u003e\u003cp\u003eBased on multi-channel nanovolt and microhm thermometer and scanning switch unit, the software can realize multi-furnace thermocouple group control and mixed verification\/calibration tasks of thermocouple and thermal resistance.\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/\/cdn.globalso.com\/panrancalibration\/1672810955545676.png\"\u003e\u003cimg alt=\"1672810955545676\" src=\"\/\/cdn.globalso.com\/panrancalibration\/1672810955545676.png\"\u003e\u003c\/a\u003e\u003c\/p\u003e\u003cp style=\"text-align: center;\"\u003e▲ Thermocouple Verification Software for Work\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/\/cdn.globalso.com\/panrancalibration\/1672810955969215.png\"\u003e\u003cimg alt=\"1672810955969215\" src=\"\/\/cdn.globalso.com\/panrancalibration\/1672810955969215.png\"\u003e\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/\/cdn.globalso.com\/panrancalibration\/1672811014167428.png\"\u003e\u003cimg alt=\"1672811014167428\" src=\"\/\/cdn.globalso.com\/panrancalibration\/1672811014167428.png\"\u003e\u003c\/a\u003e\u003c\/p\u003e\u003cp style=\"text-align: center;\"\u003e▲ Professional Report, Certificate Output\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003e2、VerificationCalibration Function List\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/\/cdn.globalso.com\/panrancalibration\/1672817107947472.png\"\u003e\u003cimg alt=\"1672817107947472\" src=\"\/\/cdn.globalso.com\/panrancalibration\/1672817107947472.png\"\u003e\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003e3、Other Software Functions\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/\/cdn.globalso.com\/panrancalibration\/1672817146442238.png\"\u003e\u003cimg alt=\"1672817146442238\" src=\"\/\/cdn.globalso.com\/panrancalibration\/1672817146442238.png\"\u003e\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eIII - Technical Parameters\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003e1、Metrology Parameters\u003c\/strong\u003e\u003c\/p\u003e\u003cdiv\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\" width=\"197\"\u003eItems\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"171\"\u003eParameters\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"242\"\u003eRemarks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\" width=\"197\"\u003eScan switch parasitic potential\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"171\"\u003e≤0.2μV\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"242\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\" width=\"197\"\u003eInter-channel data acquisition difference\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"171\"\u003e≤0.5μV  0.5mΩ\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"242\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\" width=\"197\"\u003eMeasurement repeatability\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"171\"\u003e≤1.0μV  1.0mΩ\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"242\"\u003eUsing the PR293 Series Thermometer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\u003cp\u003e\u003cstrong\u003e2、Scanner General Parameters\u003c\/strong\u003e\u003c\/p\u003e\u003cdiv\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\" width=\"139\"\u003e           Models Items\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"154\"\u003ePR160A\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"170\"\u003ePR160B\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"147\"\u003eRemarks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\" width=\"139\"\u003eNumbers of channels\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"154\"\u003e16\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"170\"\u003e12\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"147\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\" width=\"139\"\u003eStandard temperature control circuit\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"154\"\u003e2 sets\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"170\"\u003e1 set\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"147\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\" width=\"139\"\u003eDimension\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"154\"\u003e650×200×120\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"170\"\u003e550×200×120\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"147\"\u003eL×W×H(mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\" width=\"139\"\u003eWeight\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"154\"\u003e9kg\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"170\"\u003e7.5kg\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"147\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\" width=\"139\"\u003eDisplay screen\u003c\/td\u003e\n\u003ctd colspan=\"2\" valign=\"center\" width=\"324\"\u003e7.0-inch industrial touch\u003ca\u003escreen\u003c\/a\u003eresolution 800×480 pixels\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"147\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\" width=\"139\"\u003eWorking Environment\u003c\/td\u003e\n\u003ctd colspan=\"2\" valign=\"center\" width=\"324\"\u003eOperating temperature range: (-10～50)℃, non-condensing\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"147\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\" width=\"139\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd colspan=\"2\" valign=\"center\" width=\"324\"\u003e220VAC±10%，50Hz\/60Hz\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"147\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\" width=\"139\"\u003eCommunication\u003c\/td\u003e\n\u003ctd colspan=\"2\" valign=\"center\" width=\"324\"\u003eRS232\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"147\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\u003cp\u003e\u003cstrong\u003e3、Standard Temperature Control Parameters\u003c\/strong\u003e\u003c\/p\u003e\u003cdiv\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\" width=\"138\"\u003eItems\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"290\"\u003eParameters\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"182\"\u003eRemarks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\" width=\"138\"\u003eSupported sensor types\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"290\"\u003eS、R、B、K、N、J、E、T\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"182\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\" width=\"138\"\u003eResolution\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"290\"\u003e0.01℃\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"182\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\" width=\"138\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"290\"\u003e0.5℃，@≤500℃0.1%RD，@＞500℃\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"182\"\u003eType N thermocouple, excluding sensor and reference compensation error\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\" width=\"138\"\u003eFluctuation\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"290\"\u003e0.3℃\/10min\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"182\"\u003e10min maximum difference, the controlled object is PR320 or PR325\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eIV - Typical Configuration\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\u003cp\u003eZRJ-23 series intelligent thermal instrument verification system has excellent equipment compatibility and expansibility, and can support various types of electrical measuring instruments for RS232, GPIB, RS485, and CAN bus communication by adding drivers.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCore Configuration\u003c\/strong\u003e\u003c\/p\u003e\u003cdiv\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\" width=\"158\"\u003eModelsParameters\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"77\"\u003eZRJ-23A\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"77\"\u003eZRJ-23B\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"77\"\u003eZRJ-23C\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"77\"\u003eZRJ-23D\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"77\"\u003eZRJ-23E\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"73\"\u003eZRJ-23F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\" width=\"158\"\u003eNumber of be-calibrated Channels\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"77\"\u003e11\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"77\"\u003e15\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"77\"\u003e30\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"77\"\u003e45\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"77\"\u003e60\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"73\"\u003e75\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\" width=\"158\"\u003ePR160A Scanner\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"77\"\u003e\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"77\"\u003e×1\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"77\"\u003e×2\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"77\"\u003e×3\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"77\"\u003e×4\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"73\"\u003e×4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\" width=\"158\"\u003ePR160B Scanner\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"77\"\u003e×1\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"77\"\u003e\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"77\"\u003e\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"77\"\u003e\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"77\"\u003e\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"73\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\" width=\"158\"\u003ePR293A Thermometer\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"77\"\u003e○\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"77\"\u003e○\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"77\"\u003e○\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"77\"\u003e●\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"77\"\u003e●\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"73\"\u003e●\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\" width=\"158\"\u003ePR293B Thermometer\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"77\"\u003e●\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"77\"\u003e●\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"77\"\u003e●\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"77\"\u003e\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"77\"\u003e\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"73\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\" width=\"158\"\u003eStandard temperature control function supportMaximum number of calibration furnaces\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"77\"\u003e×1\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"77\"\u003e×2\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"77\"\u003e×4\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"77\"\u003e×6\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"77\"\u003e×8\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"73\"\u003e×10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\" width=\"158\"\u003eManual lift table\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"77\"\u003e\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"77\"\u003e\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"77\"\u003e×1\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"77\"\u003e×2\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"77\"\u003e×3\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"73\"\u003e×4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\" width=\"158\"\u003eElectric lift table\u003c\/td\u003e\n\u003ctd colspan=\"6\" valign=\"center\" width=\"458\"\u003e×1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\" width=\"158\"\u003ePR542 Thermometer thermostat\u003c\/td\u003e\n\u003ctd colspan=\"6\" valign=\"center\" width=\"458\"\u003e●\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\" width=\"158\"\u003eProfessional software\u003c\/td\u003e\n\u003ctd colspan=\"6\" valign=\"center\" width=\"458\"\u003e●\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003eNote 1:When using dual-channel standard temperature control, the number of be-calibrated channels of each group of scanners should be subtracted by 1 channel, and this channel will be used for the standard temperature control function.\u003c\/p\u003e\n\u003c\/div\u003e\u003cp\u003eNote 2:The maximum number of supported calibration furnaces refers to the number of calibration furnaces that can be independently operated when standard temperature control is used. The calibration furnaces with their own temperature control are not subject to this restriction.\u003c\/p\u003e\u003cp\u003eNote 3: When using homopolars comparison method to verify the standard thermocouple, the PR293A thermometer must be selected.\u003c\/p\u003e\u003cp\u003eNote 4:The above configuration is the recommended configuration and can be adjusted according to the actual usage.\u003c\/p\u003e\u003c!----\u003e\u003cdiv class=\"clear\"\u003e\u003c\/div\u003e","brand":"Warehouse","offers":[{"title":"Default Title","offer_id":53792151240888,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/7224\/3128\/files\/edrth-1.png?v=1784607274","url":"https:\/\/temptechsupply.com.au\/products\/zrj-23-series-intelligent-thermal-instrument-verification-system","provider":"TechTemp Supply","version":"1.0","type":"link"}